{"id":7157,"date":"2023-02-01T11:50:05","date_gmt":"2023-02-01T11:50:05","guid":{"rendered":"https:\/\/www.atglobalndt.com\/dev\/?p=7157"},"modified":"2023-02-24T03:31:18","modified_gmt":"2023-02-24T03:31:18","slug":"eeciflux-multi-directional-magnetic-particle-inspection-solution-2","status":"publish","type":"post","link":"https:\/\/www.atglobalndt.com\/dev\/index.php\/2023\/02\/01\/eeciflux-multi-directional-magnetic-particle-inspection-solution-2\/","title":{"rendered":"EECIFLUX MULTI-DIRECTIONAL MAGNETIC PARTICLE INSPECTION SOLUTION"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]<\/p>\n<div align=\"justify\"><span style=\"color: #444343; font-family: Trebuchet MS, Arial, Helvetica, sans-serif;\">The EECIFLUX multi-directional bench offers an efficient and reliable method to carry out magnetic particle inspection with minimal operator intervention.<\/span><\/div>\n<div align=\"justify\"><span style=\"color: #444343; font-family: Trebuchet MS, Arial, Helvetica, sans-serif;\">\u00a0<\/span><\/div>\n<div align=\"justify\"><span style=\"color: #1895db; font-family: Trebuchet MS, Arial, Helvetica, sans-serif;\"><b>Highlights of the EECIFLUX multi-directional MPI bench solution:<\/b><\/span><\/div>\n<div align=\"left\">\n<ul>\n<li>True multi-directional magnetisation to identify cracks in all orientations in a single shot<\/li>\n<li><span style=\"color: #444343; font-family: Trebuchet MS, Arial, Helvetica, sans-serif;\">AC and HWDC\u00a0magnetisation\u00a0<\/span><\/li>\n<li>Advanced automation to control and customise test cycles<\/li>\n<li>Inspect in multi-directional or individual magnetisation modes<\/li>\n<li>User selectable magnetising current<\/li>\n<li>Multiple mechanical attachments to adapt to components of various sizes and profiles<\/li>\n<li>Plan, store and recall custom test cycles to suit inspection requirements of various components<\/li>\n<li>Built in demagnetiser to remove residual magnetisation of tested components<\/li>\n<li>Compatible to be used with dry magnetic powders, wet powders and aerosols<\/li>\n<li>Emergency cut-off switch and interlocks to maintain safety<\/li>\n<li>Intuitive HMI program for easy and efficient operations<\/li>\n<\/ul>\n<\/div>\n<div align=\"justify\"><span style=\"color: #444343; font-family: Trebuchet MS, Arial, Helvetica, sans-serif;\">\u00a0<\/span><\/div>\n<div align=\"justify\"><span style=\"font-family: Trebuchet MS, Arial, Helvetica, sans-serif;\"><span style=\"color: #444343;\">For more information and to discuss your testing requirements, please get in touch with our\u00a0<\/span><a title=\"sales team\" href=\"mailto:ndtsales@eecindia.com?subject=Enquiry:%20EECIFLUX%20multi-directional%20bench%20unit\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #1895db;\">sales team<\/span><\/a><span style=\"color: #444343;\">.<\/span><\/span><\/div>\n\n<p>&nbsp;<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"[vc_row][vc_column][vc_column_text] The EECIFLUX multi-directional bench offers an efficient and reliable method to carry out magnetic particle inspection with minimal operator intervention. \u00a0 Highlights of the EECIFLUX multi-directional MPI bench solution: True multi-directional magnetisation to identify cracks in all orientations in a single shot AC and HWDC\u00a0magnetisation\u00a0 Advanced automation to control and customise test cycles Inspect[&#8230;]","protected":false},"author":3,"featured_media":7160,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_editorskit_title_hidden":false,"_editorskit_reading_time":0,"_editorskit_is_block_options_detached":false,"_editorskit_block_options_position":"{}","_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[166,1],"tags":[298],"_links":{"self":[{"href":"https:\/\/www.atglobalndt.com\/dev\/index.php\/wp-json\/wp\/v2\/posts\/7157"}],"collection":[{"href":"https:\/\/www.atglobalndt.com\/dev\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.atglobalndt.com\/dev\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.atglobalndt.com\/dev\/index.php\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.atglobalndt.com\/dev\/index.php\/wp-json\/wp\/v2\/comments?post=7157"}],"version-history":[{"count":0,"href":"https:\/\/www.atglobalndt.com\/dev\/index.php\/wp-json\/wp\/v2\/posts\/7157\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.atglobalndt.com\/dev\/index.php\/wp-json\/wp\/v2\/media\/7160"}],"wp:attachment":[{"href":"https:\/\/www.atglobalndt.com\/dev\/index.php\/wp-json\/wp\/v2\/media?parent=7157"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.atglobalndt.com\/dev\/index.php\/wp-json\/wp\/v2\/categories?post=7157"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.atglobalndt.com\/dev\/index.php\/wp-json\/wp\/v2\/tags?post=7157"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}